Veritas Software SCSI & RAID Devices Driver Download For Windows 10

Veritas Cluster Server Agent for SQL Server The software described in this book is furnished under a license agreement and may be used only in accordance with the terms of the agreement. Product version: 6.0.1 Document version: 6.0.1 Rev 2. Veritas software required is Veritas Cluster Server and Cluster File System. The setup of the 3320 is not given in detail. The following docs should be referenced for complete install / setup. Veritas Soft Solutions is one of the leading software consulting, services and business process outsourcing organization in India. Veritas InfoScaleTM 7.4.2 for Windows Software Compatibility. A virtual machine created using Failover Cluster Manager cannot be monitored and managed using System Center Virtual Machine Manager 2012 R2 and 2016 on Windows Server 2016, 2019. Vmware vMotion is supported only if the guest storage configuration involves non-shared SCSI bus disks.

Sun StorEdge 3000 Family Installation, Operation, and Service Manual

C H A P T E R 5
Software Management Tools

This chapter describes the software management tools used for monitoring and managing the Sun StorEdge 3120 SCSI array. Topics include the following:


Note - For other supported software, see the Release s for your array.


5.1 Overview of Provided Software

This section describes the software management tools available for monitoring and managing the Sun StorEdge 3120 SCSI array with in-band connections.

The following software management tools are provided on the Sun StorEdge 3000 Family Professional Storage Manager CD, provided with your array. The Sun StorEdge 3000 Family Documentation CD provides the related user guides.

  • Sun StorEdge Configuration Service. Provides monitoring functions. Refer to the Sun StorEdge 3000 Family Configuration Service User's Guide for in-band setup procedures.
  • Sun StorEdge Diagnostic Reporter. Provides event monitoring and notification. Refer to the Sun StorEdge 3000 Family Diagnostic Reporter User's Guide for information.
  • Sun StorEdge Command-Line Interface (CLI). A command-line interface utility that provides script-based management. Refer to the Sun StorEdge 3000 Family CLI User's Guide for additional CLI information.

For details on how to install Sun StorEdge Configuration Service, Sun StorEdge Diagnostic Reporter, or the Sun StorEdge CLI software, refer to the Sun StorEdge 3000 Family Software Installation Manual.

5.2 Monitoring with the Sun StorEdge Configuration Service

Sun StorEdge Configuration Service supports standalone JBOD arrays. However, because the Sun StorEdge 3120 SCSI array does not have a RAID controller or RAID controller firmware to manage the disks, this software support is limited to enabling JBOD support and viewing component and alarm characteristics.

See Viewing Component and Alarm Characteristics.

5.2.1 Enabling JBOD Support

Use JBOD support only when you have a SCSI array connected directly to a host. This enables you to monitor peripheral device condition and events.


Note - Enabling JBOD support may impact I/O performance.


To monitor peripheral device condition and events for a JBOD device from the Sun StorEdge Configuration Service Console, you first need to enable JBOD support.

1. Select View Agent Options Management.

The Agent Options Management window is displayed.

2. Select the Enable JBOD Support check box.

Veritas software scsi & raid devices driver download for windows 10 download

3. To immediately display the JBOD in the main window, you need to probe for new inventory. Select View View Server and click Probe.

4. Click OK.

The JBOD is displayed in the main window.

In a single-bus configuration, both ports of the JBOD array are connected to one HBA on the server, as shown in the following example.

FIGURE 5-1 Single-bus Configuration


In a dual-bus configuration, each port is connected to its own HBA, as shown in the following example.

FIGURE 5-2 Dual-bus Configuration


Note - In a dual-bus configuration, if each port is connected to different servers, the program can only monitor the JBOD from the server connected to port B.


5.2.2 Viewing Component and Alarm Characteristics

In Sun StorEdge Configuration Service, to view environmental component and alarm characteristics, use the View Enclosure window or, for some components, the main window.

You can also view environmental and drive components using the Sun StorEdge CLIL show enclosure-status command. For details, see show enclosure-status.

Main Window

In the main window, device states are color-coded and symbol-coded so that it is easy to identify when a device is in a state that requires attention. The status is propagated along the device tree, enabling you to trace a failure down to the device level. See TABLE 5-1for device status details.

TABLE 5-1 Device Status State

Color

Symbol

State

Purple

None

The group, server, or device is online.

White

None

The user has not logged into this server.

Yellow

One or more components of this group or server are not working properly, but the array is still functional.

Red

One or more components of this group or server are not working. For instance, a disk drive failure or an enclosure with a failed fan would warrant a critical state icon.

Gray

The group, server, or device is unresponsive.


To view the cause of a critical or degraded device status, review the event log. For details on the event log, refer to the Sun StorEdge 3000 Family Configuration Service User's Guide.

View Enclosure Window

The View Enclosure window displays the component and alarm characteristics for a JBOD device. The window displays the status for environmental components including the fan, power supply, and temperature sensor.

Veritas Software SCSI & RAID Devices Driver Download For Windows 10

To view the environmental component and alarm characteristics of a SCSI array from the Sun StorEdge Configuration Service Console, perform the following steps.

1. Select the EMU (SCSI) or SES (Fibre Channel) icon.

2. Choose View View Enclosure.

To display FRU ID information, click View FRU.

FIGURE 5-3 View Enclosure Dialog Box


5.3 Event Messages from the Sun StorEdge Diagnostic Reporter

Sun StorEdge Diagnostic Reporter supports standalone JBOD arrays. However, triggered event notification is limited to environmental and hard drive failures. Refer to the Sun StorEdge 3000 Family Diagnostic Reporter User's Guide for more information.

5.4 Monitoring with the Sun StorEdge CLI

The Sun StorEdge CLI supports JBOD arrays. However, because JBOD arrays do not have a RAID controller or RAID controller firmware to manage the disks, this CLI support is limited to the following sccli commands:

  • about
  • exit
  • help
  • quit
  • select
  • set led
  • show configuration
  • show enclosure-status
  • show frus
  • show inquiry-data
  • show led-status
  • show safte-devices
  • version

about

The about command displays version and copyright information.

The following example shows the about text for the CLI:


exit

This command exits the interactive mode.

help

The help command displays a short synopsis of the available commands.


If no command is specified, basic usage information is displayed.

quit

The quit command exits the interactive mode.

select

The select command selects a new device to which subsequent commands are issued. If no device is specified, and more than one choice exists, a menu of choices is displayed. This command should not be used on the command line because a select command is implicitly done if no device name is specified.


For example:

Veritas software scsi & raid devices driver download for windows 10 download

set led

This command illuminates the LED in the enclosure adjacent to the specified disk (or slot). For JBODs, specify a disk device using a Solaris device name such as sd31 or c1t0d0s2, or specify a slot number. Use the show led-status command to show the status of the identified disk drive.


Note - Selecting a slot by disk name is not supported in split-bus (dual-bus) enclosure configurations because the enclosure services processor resides on only one of the internal buses and the CLI may not be able to unambiguously determine the slot location of a particular device. In such configurations, use the show enclosure-status command and the documentation provided with your enclosure to determine the correct slot number instead.


To illuminate a disk drive LED, use the following parameters:


In the following example, the LED adjacent to the drive with SCSI address 3 in the enclosure is set to on:

TABLE 5-2 Arguments for set led

Argument

Description

slot n

Illuminates the drive LED for specified disk drive slot.

disk sdn

Illuminates the drive LED for the specified Solaris disk drive slot.

disk cXtYdZ

Illuminates the drive LED for the specified Solaris disk drive slot.

ch.id

Illuminates the drive LED for the specified drive within a RAID subsystem.

{on | off}

Specify whether to illuminate the drive LED.


show configuration

This command displays the array configuration including inquiry information, FRU information, and the enclosure status which includes the status for the fan, power supply, temperature sensor, and drive slots. The configuration can be displayed onscreen, or written to the specified file. The output is plain text by default, but XML output may be obtained by specifying the --xml option.


TABLE 5-3 Arguments for show configuration

Argument

Description

{--xml | -x}

If the -x or --xml options are specified, XML output is generated.

filename

Specify the filename for the configuration file that you want to show.


Enclosure status values include:

Status

Description

OK

This component has a status of OK.

Absent

This component is absent.

Fault

The component is exhibiting a fault condition.

Unknown

This component status is not available.


The following example writes the configuration information to the myconfig.xml file.

The following example shows a portion of the JBOD configuration.


show enclosure-status

The show enclosure-status command shows the status for all chassis components including SAF-TE information, fan, power supply, temperature sensor, and drive slot status.


Note - In dual-bus configurations, half the drives display a status of Absent. The drives are present, but because of a SAF-TE design limitation, the information does not display.


Enclosure status values include:

Status

Description

OK

This component has a status of OK.

Absent

This component is absent.

Fault

The component is exhibiting a fault condition.

Unknown

This component status is not available.


Disk slots refer to the backplane FRU to which disks are connected.


Note - The Enclosure SCSI Channel Type values include single-bus and dual-bus. Throughout the documentation and the CLI, the term 'split-bus' is interchangeable with the term 'dual-bus.' For details on configuring an array, see Connecting Sun StorEdge 3120 SCSI Arrays to Hosts.


The following example shows the enclosure status for a Sun StorEdge 3120 SCSI device.


show frus

This command displays field-replaceable units (FRU) ID and status information. All FRU information is retrieved from the SAF-TE device.

FRU status values include:

Status

Description

OK

All subcomponents of this FRU have a status of OK.

Fault

One or more of the FRU components is exhibiting a fault condition.


The following examples return all FRU information for the JBOD unit:


The following example shows a partial list of the FRUs in a Sun StorEdge 3120 SCSI device:


show led-status

This command displays the status of the LED adjacent to the specified disk drive slot in the array enclosure or expansion chassis.

To show the status of LVD JBOD enclosures, use the following parameters:

The following example shows the status of the LED adjacent to the disk assigned to drive slot 3 for an expansion chassis:


TABLE 5-4 Arguments for show led

Argument

Description

slot n

Shows the status for the LED adjacent to the specified disk drive slot. This argument is not accepted for RAID controllers.

disk sdn

Shows the status for the LED adjacent to the specified Solaris disk drive slot. This argument is not accepted for split-bus chassis.

disk cXtYdZ

Shows the status for the LED adjacent to the specified Solaris disk drive slot. This argument is not accepted for split-bus chassis.

ch.id

Shows the status for the LED adjacent to the specified drive within a RAID subsystem.


show safte-devices

This command displays information returned by the SAF-TE device embedded in SCSI LVD RAID enclosures or JBODs.

The output includes the serial number of the chassis in which it is installed, the vendor and product IDs and SAF-TE firmware revision, and the 'SAF-TE firmware package' revision, which refers to firmware for other microprocesses in the chassis that are managed by the SAF-TE processor.

The following example shows the SAF-TE device information for a Sun StorEdge 3120 SCSI array.


version

The version command displays the version number of the CLI.

For example:

Veritas software scsi & raid devices driver download for windows 10 xp

5.5 Managing Disks in the Sun StorEdge 3120 SCSI Array

Use your standard host system disk management utilities for all disk management in a JBOD array, such as partitioning and formatting. Refer to your host system documentation for more information about disk management.

For maintenance and troubleshooting information, see Maintaining and Troubleshooting Your Array.

5.6 Enabling VERITAS DMP in a Single-Bus Configuration

The Sun StorEdge 3120 SCSI array supports Veritas Dynamic Multi-Pathing (DMP) software.


Note - For other supported software, see the Release s for your array.


To enable VERITAS Dynamic Multi-Pathing (DMP) support on VERITAS Volume Manager Version 3.2, ensure the HBA device SCSI initiator IDs are unique and then start the system. Perform the following steps.

1. Create a single-bus, multi-initiator configuration that links two cables to two different HBAs.

For details about creating a single-bus multi-initiator configuration, see A Single-Bus, Multi-Initiator JBOD Configuration.

2. Stop the server and at the ok prompt, type:

3. Issue the remaining commands on only one of the paths.

4. Edit or create the nvramrc to set the SCSI-initiator-id to a non-conflicting ID for these devices based on the information returned in step 2.

5. From the OBP type:


Veritas Software Scsi & Raid Devices Driver Download For Windows 10 Xp

6. Press Ctrl-c, and store the nvramrc by typing:

7. Set the system to use the nvramrc and reset auto-boot by typing:


Veritas Software Scsi & Raid Devices Driver Download For Windows 10 32-bit

8. Reset the configuration by typing:

9. Reboot the hosts. A system reboot is required to implement these changes.


Note - SCSI arrays require a license from VERITAS in order to enable any of its advanced features. Refer to VERITAS Volume Manager Release s or contact VERITAS Software Corporation for licensing terms and information.



Sun StorEdge 3000 Family Installation, Operation, and Service Manual816-7956-10

Veritas Software Scsi & Raid Devices Driver Download For Windows 10 64-bit

Copyright © 2004, Sun Microsystems, Inc. All rights reserved.